以下是:M250-50A5宝钢销售的产品参数
产品参数 |
---|
产品价格 | 2/吨 |
---|
发货期限 | 3天内 |
---|
供货总量 | 50000 |
---|
运费说明 | 电议 |
---|
最小起订 | 1 |
---|
质量等级 | 精品 |
---|
是否厂家 | 是 |
---|
产品材质 | 冷轧 |
---|
产品品牌 | 宝武日本进口 |
---|
产品规格 | 0.08-0.65 |
---|
发货城市 | 上海武汉 |
---|
产品产地 | 上海武汉 |
---|
加工定制 | 粗加工 |
---|
产品型号 | 多种 |
---|
可售卖地 | 全国 |
---|
质保时间 | 一年 |
---|
适用领域 | 电器马达电机变压器磁感器互感器稳压器继电器电磁开关新能源电机电动汽车变压器军工电机发电机组航天造船汽车等 |
---|
是否进口 | 否 |
---|
品名 | 电工钢 冷轧无取向电工钢 冷轧取向电工钢卷冷轧取向硅钢 取向电工钢冷轧无取向硅钢冷轧无取向硅钢 |
---|
规格 | 0.08 0.1 0.05 0.18 0.2 0.23 0.27 0.3 0.35 0.5 0.65 1.0mm |
---|
包装 | 原厂精包装 |
---|
用途 | 电器马达电机变压器磁感器互感器稳压器继电器电磁开关新能源电机电动汽车变压器军工电机发电机组航天造船汽车等 |
以下是:M250-50A5宝钢销售的图文视频
M250-50A5宝钢销售,鹿程国际贸易有限公司专业从事M250-50A5宝钢销售,联系人:鹿丙伟,电话:021-56152236、13764370568,QQ:871956683,发货地:宝山区蕰川公路777号宝钢厂区607-609室发货到山西省 晋城市 沁水县、阳城县、陵川县、泽州县、高平县,以下是M250-50A5宝钢销售的详细页面。 山西省,晋城市 晋城市历史悠久,上世纪出土高都、塔水河、下川等史前遗址。东晋置郡,北魏置州,清置府,是一座千年古城。诞生了刘羲叟、李俊民、张慎言、王国光、陈廷敬等历史名人。全市文物古迹众多,代表景点有冶底岱庙、青莲寺、开化寺、程颢书院、柳氏民居、湘峪古堡、天官王府、皇城相府、长平之战遗址、羊头山石窟、析城山、王莽岭等。晋城市古为煤铁之乡,有“九头十八匠”之称。是战国“阳阿古剑”产地,所产泽州铁器、兰花炭质地优良 。蟒河、历山等保护区,生长有猕猴、大鲵等稀有动物,素有山西"生物资源宝库"之称。
想要了解M250-50A5宝钢销售产品的魅力?视频为你揭晓答案!
以下是:M250-50A5宝钢销售的图文介绍
电工钢硅钢片硅钢是一种硅铁合金。用硅钢轧制的片材是电工领域中应用广的软磁材料,因而硅钢片又称电工钢片。硅钢片广泛用于电动机、发电机、变压器、扼流圈、电磁机构、继电器及测量仪表中电机工业大量使用厚度为0.35~0.50mm的硅钢片,用于:中型旋转机,压缩电机,通用马达,小型精密电机,电动汽车,压缩机,通用电机,电源变压器,精密变压器,节能电机,焊机变压器,稳压器,磁性密封器,加速器用电磁铁,汽车电机等;在电信高频技术中常用0.05~0.20mm的薄带钢片,以便更有效地降低涡流损耗。热轧硅钢片厚度为0.35~0.50mm,密度为7.55~7.70g/cm3,多用于大、中、小型交、直流电动机;冷轧无取向硅钢片厚度为0.35~0.50mm,密度为7.65~7.75g/cm3,多用于大型交流发电机、电动机,大、中、小型交、直流电动机;冷轧取向硅钢片厚度为0.23mm 0.27mm 0.3mm 0.35mm,密度为7.65g/cm3,多用于电力变压器、油浸式变压器,干式变压器,电抗器、磁放大器等;冷轧取向薄带厚度为0.05~0.20mm,多用于无线电高频变压器。
电工钢硅钢片 电工钢亦称硅钢片,是电力、山西晋城附近电子和军事工业不可缺少的金属材料,亦是产量 的功能性材料,主要用作各种电机、山西晋城附近发电机和变压器的铁芯。比总损耗(铁损) specific total loss (iron loss)比总损耗是在磁极化波形保持正弦,其峰值和频率为特定值时,单位质量材料所消耗的总功率,比总损耗用符号 P(Jm/f)表示,单位为 W/kg。例:P1.5/50表示在 磁极化强度为 1.5T、山西晋城本地频率为 50Hz 时的比总损耗。3.2 磁极化强度 magnetic polarizationQ/BQB 480-20212磁极化强度是指试样受交变磁化时,特定磁场强度峰值的磁极化强度峰值,其符号为J(H),单位为 T(特斯拉)。例:J5000表示对应于磁场强度峰值为 5000A/m 下的磁极化强度峰值。4 分类本文件的材料的等级是根据磁极化强度在1.5T、山西晋城本地频率在50Hz下的 比总损耗名义值P1.5/50(W/kg)、山西晋城本地材料公称厚度进行牌号分类
鹿程国际贸易有限公司自2012年上市以来一直保持稳定增长,公司将秉着“创新、、团结、诚信”的理念,坚持稳健经营、持续创新,为用户提供多好的解决方案、 山西晋城新能源电工钢产品和服务,为社会可持续发展贡献力量。
电工钢硅钢片In addition to the types listed above, there are also some special purpose electrical steel plates, such as 0.15 and 0.20mm thick 3% Si cold-rolled non oriented silicon steel strips and 0.025, 0.05, and 0.1mm thick 3% Si cold-rolled oriented silicon steel strips, used for medium and high-frequency motors, transformers, and pulse transformers; 0.7mm thick 3% Si high-strength cold-rolled non oriented silicon steel plate for relays and power switches; High strength cold-rolled electrical steel plate for new high-speed motor rotors; Low carbon electrical steel hot-rolled thick and cold-rolled plates for magnetic shielding and high-energy accelerator electromagnets such as medical magnetic resonance tomography scanners; 4.5% to 6.5% Si high silicon steel plates for high-frequency motors, transformers, and magnetic shielding.Generally, motors, transformers, and other electrical components are required to have high efficiency, low power consumption, small size, and light weight. Electrical steel plates are usually guaranteed to have magnetic properties based on core loss and magnetic induction strength [1] [2]. The requirements for the performance of electrical steel plates are as follows:Low core loss (PT)Iron core loss refers to the ineffective electrical energy consumed by an iron core when magnetized in an alternating magnetic field of ≥ 50Hz, abbreviated as iron loss, also known as alternating loss, and its unit is W/kg. The ineffective electrical energy consumed due to various obstacles caused by magnetic flux changes not only loses electrical energy through the heating of the iron core, but also causes temperature rise of the motor and transformer. The iron loss (PT) of electrical steel includes three parts: hysteresis loss, eddy current loss (Pe), and anomalous loss (Pa). Electrical steel plates have low iron loss, which can save a lot of electricity, prolong the operating time of motors and transformers, and simplify cooling devices. Due to the iron loss of electrical steel plates, which accounts for 2.5% to 4.5% of the annual electricity generation in various countries, countries always try their best to reduce iron loss in the production of electrical steel plates, and use iron loss as the most important indicator to assess the magnetic properties of products. The iron loss value of products is used as the basis for classifying product grades. Cold rolled oriented electrical steel: Cold rolled oriented electrical steel is a high-end product in the field of electrical steel. Compared with cold rolled non oriented electrical steel, its magnetism has strong directionality; It has superior high magnetic permeability and low loss characteristics in the direction of easy magnetization rolling. The iron loss of oriented steel strip in the rolling direction is only 1/3 of that in the transverse direction, and the ratio of magnetic permeability is 6:1. Application: The main purpose of cold-rolled oriented silicon steel strip is for transformer manufacturing.Full process cold rolled non oriented silicon steel coating: The surface of the full process cold rolled silicon steel is coated with a semi transparent insulation coating, which has different codes in different standards. Taking Baosteel‘s Q/BQB 480 2014 as an example:
M250-50A5宝钢销售,鹿程国际贸易有限公司为您提供M250-50A5宝钢销售产品案例,联系人:鹿丙伟,电话:021-56152236、13764370568,QQ:871956683,发货地:宝山区蕰川公路777号宝钢厂区607-609室。