产品视频展示,助您洞悉B35A440现货钢厂极化高强型产品的每一处细节。让购买决策变得轻松简单,为您带来更好的购物体验。


以下是:B35A440现货钢厂极化高强型的图文介绍


多年行业经验专注 江苏连云港新能源电工钢行业,只为您提供放心的产品。货源稳定、库存充足、满足客户量大的需求。工艺严选、厂家成熟、材质直供。



电工钢硅钢片Electrical steel, also known as silicon steel sheet, is an indispensable metal material in the power, electronics, and military industries, and is also the largest functional material in production. It is mainly used as the iron core for various motors, generators, and transformers. Since it is a functional material, its performance testing also revolves around "function". These indicators are often mentioned in trade and processing processes, and a brief understanding can help everyone better carry out their work. The performance testing of electrical steel mainly includes the following aspects: magnetic inspection, stacking coefficient inspection, coating adhesion inspection, repeated bending inspection, size and shape surface inspection, and conventional mechanical property inspection. In addition to the types of products listed above, there are also some special purpose electrical steel plates, such as 0.15 and 0.20mm thick 3% Si cold-rolled non oriented silicon steel strips and 0.025, 0.05, and 0.1mm thick 3% Si cold-rolled oriented silicon steel strips, which are used as intermediate and intermediate grade High frequency motors and transformers, as well as pulse transformers, etc; 0.7mm thick 3% Si high-strength cold-rolled non oriented silicon steel plate for relays and power switches; High strength cold-rolled electrical steel plate for new high-speed motor rotors; Low carbon electrical steel hot-rolled thick and cold-rolled plates for magnetic shielding and high-energy accelerator electromagnets such as medical magnetic resonance tomography scanners; 4.5% to 6.5% Si high silicon steel plates for high-frequency motors, transformers, and magnetic shielding. Generally, motors, transformers, and other electrical components are required to have high efficiency, low power consumption, small size, and light weight. Electrical steel plates are usually guaranteed to have magnetic properties based on core loss and magnetic induction strength. Magnetic induction strength is the number of magnetic lines passing through a unit cross-sectional area of the iron core, also known as magnetic flux density. It represents the material‘s magnetization ability, measured in T. The magnetic induction strength of electrical steel plates is high, and the excitation current (also known as no-load current) of the iron core is reduced. Copper and iron losses are also reduced, which can save electrical energy. When the power of the motor and transformer remains constant, the magnetic induction intensity is high, and the design Bm can be increased. The cross-sectional area of the iron core can be reduced, which reduces the volume and weight of the iron core, and saves the amount of electrical steel plates, wires, insulation materials, and structural materials used. This can reduce the total loss and manufacturing cost of the motor and transformer, and is beneficial for the manufacturing, installation, and transportation of large transformers and motors. The main requirements for the performance of silicon steel are: 1. Low iron loss is the most important indicator of the quality of silicon steel sheets. Various countries classify grades based on iron loss values, with the lower the iron loss, the higher the grade. 2. Under strong magnetic fields, the magnetic induction intensity (magnetic induction) is high, which reduces the volume and weight of the iron core of the motor and transformer, saving silicon steel sheets, copper wires, and insulation materials. 3. The surface is smooth, flat, and the thickness is uniform, which can improve the filling coefficient of the iron core. 4. Good lamination performance is more important for manufacturing micro and small electric motors. 5. The adhesion and weldability of the surface insulation film are good, which can prevent corrosion and improve the punching performan




电工钢硅钢片:本文件规定了公称厚度为 0.15mm、江苏连云港0.20mm、江苏连云港当地0.25mm、江苏连云港当地0.27mm、江苏连云港当地0.30mm 和 0.35mm 全工艺冷轧中频无取向电工钢带的术语和定义、江苏连云港当地分类和代号、江苏连云港当地一般要求、江苏连云港当地技术要求、江苏连云港当地检验和试验、江苏连云港当地包装、江苏连云港当地标志及检验文件等要求。本文件适用于宝山钢铁股份有限公司生产的、江苏连云港当地用于频率在 100Hz-10000Hz 磁路结构的、江苏连云港当地以终退火状态交货的全工艺冷轧无取向电工钢带产品(以下简称产品)。2 规范性引用文件下列文件中的内容通过文中的规范性引用而构成本文件必不可少的条款。其中,注日期的引用文件,仅该日期对应的版本适用于本文件;不注日期的引用文件,其 版本(包括所有的修改单)适用于本文件。GB/T 228.1-2010 金属材料拉伸试验 第 1 部分:室温实验法GB/T 2521.1 全工艺冷轧电工钢 第 1 部分:晶粒无取向钢带(片)GB/T 2522GB/T 2791电工钢片(带)表面绝缘电阻、江苏连云港当地涂层附着性测试方法粘结剂 T 剥离强度试验方法 挠性材料对挠性材料GB/T 2900.60 电工术语 电磁学GB/T 3655 用爱泼斯坦方圈测量电工钢片(带)磁性能的方法GB/T 4340.1 金属材料维氏硬度试验 第 1 部分:试验方法GB/T 8170 数值修约规则与极限数值的表示和判定GB/T 9637GB/T 10129电工术语磁性 材料与元件电工钢片(带)中频磁性能测量方法GB/T 17505 钢及钢产品交货一般技术要求GB/T 18253 钢及钢产品检验文件的类型GB/T 19289 电工钢片(带)的密度、江苏连云港当地电阻率和叠装系数的测量方法YB/T 4292 电工钢带(片)几何特性测试方法Q/BQB 400-2020 冷轧产品的包装、江苏连云港当地标志及检验文件IEC 60404-8-8 Specifications for individual materials –Thin electricalsteel strip and sheet for use at medium frequencies




电工钢硅钢片:电工钢钢板经冲片、江苏连云港本地剪切、江苏连云港本地弯曲会引入残余应力,导致磁性能劣化。应力退火(SRA)可以残余应力对磁畴移动与转动的阻碍作用,恢复电磁性能。E.2 在钢板或叠铁心的状态下进行应力退火的注意事项如下。1). 避免氧化和渗碳为了防止氧化应力退火应该在保护气氛下进行,通常是 10%以下氢气(H2)和 90%以上氮气(N2)、江苏连云港本地100%氮气(N2)或者氨分解气氛的非爆炸性保护气氛,露点控制在 0℃以下。冲压加工过程引入的冲压油在退火前应完全去除,防止在退火中发生渗碳,劣化产品磁性。2). 退火温度及保持时间退火温度指材料温度,750℃为宜。为使得钢板各部分退火均匀,需要调整温度与保持时间。温度太低不足以残余应力的影响,温度太高会破坏涂层绝缘性。3). 冷却时间应当避免急剧冷却使材料产生应力应变。冷却时间根据电工钢退火数量进行调整。对于退火小吨位数量时,可按每小时不超过 25℃ 的冷却速度冷却到 350℃,以避免冷却过程中产生应力应变。对于退火大吨位数量时,应采取更加缓慢的冷却速率,以期获得 效果。
点击查看鹿程国际贸易有限公司的【产品相册库】以及我们的【产品视频库】